Product Line-up
LIPIDURE®-CR2001, LIPIDURE®-CR3001, and LIPIDURE®-NH01

| Product | Functional Group : X | Size | Appearance |
|---|---|---|---|
| LIPIDURE®-CR2001 | Photoreactive | 1g, 10g, 100g | White powder |
| LIPIDURE®-CR3001 | Alkoxy silane | 1g, 10g, 100g | White powder |
| LIPIDURE®-NH01 | NH2 | 10g, 100g, 1kg | 5 wt% aqueous solution |
How to use
procedures of dissolution

*LIPIDURE®-CM5206 might take time for 16hr or more for dissolution
Performance
Improvement of Lubricity
Procedure
- Cast coat (0.12 mg/cm2) and immobilize with LIPIDURE®-CR2001 on the PET slide.
- Set the Surface Property Tester (SHINTO Scientific Co., Ltd.).
- Measure the dynamic friction coefficient on the surface in physiological saline.
Measurement Condition
- Travel speed: 10 mm/sec
- Travel distance: 20 mm
- Contact: 10 mm stainless ball (point contact)
- Weight of load: 200 g
- Load converter: 9.8 N
- Number of measurements: 5 cycles (1 cycle = going and returning)

Hydrophilic coating for silicone
A silicone rubber sheet was modified with LIPIDURE®-CR3001. Contact angle (air in water) of the CR3001-modified surface was measured to confirm the improvement of hydrophobicity.
Silicone Rubber Without Coating

Silicone Rubber Treated With LIPIDUREⓇ-CR3001

Hydrophilization of silicone rubber surface
For more product information and performance date, contact us for the details.